Automated TekExpress USB2 (10.2.5) Product: USB2 Version: 10.2.5 Date : Feb-2018 Installation Instructions. ================================================================================ Minimum System Requirements Real-time oscilloscopes - Tektronix DPO/DSA/MSO70000C, D, DX and SX series oscilloscopes - Tektronix DPO7000C series oscilloscopes - Tektronix MSO/DPO5000 and MSO/DPO5000B series oscilloscopes Tektronix AWG instruments - AWG70001A, AWG70002A, AWG7102, AWG7122B, AWG7122C, AWG5014B, AWG5014C, AWG5012C, AWG5002C, AWG5202, AWG5204 and AWG5208 Probes - Two TCA-SMA adapters (if using DPO/DSA/MSO70000) - TCP0030A or TCP202/A probe - TDP1500, TDP3500, or P6248 differential probe - TAP1500 or P6245 single-ended probe Host test fixtures - USB2SIGQUAL fixture set (USB-IF host/device SQ) - USB2/3_DD fixture (USB-IF Drop-Droop fixture) - TDSUSBF (Tek fixture) Device test fixtures - USB2SIGQUAL fixture set (USB-IF host/device SQ) - USB2/3_DD fixture (USB-IF Drop-Droop fixture) - TDSUSBF (Tek fixture) Firmware - TekScope 10.8.0 and later Processor Same as the oscilloscope Operating System Windows 7 (64-bit only) SP1 Windows 7 with user account settings set as 'Never Notify'. Windows 10 Memory Same as the oscilloscope Hard Disk Same as the oscilloscope Display Super VGA resolution or higher video adapter (800 x 600 minimum video resolution for small fonts or 1024 x 768 minimum video resolution for large fonts). The application is best viewed at 96 dpi display settings 1 Software Microsoft Internet Explorer 7.0 SP1 or later, or other Web browser for viewing reports. Adobe Reader software 7.0 or later for viewing portable document format (PDF) files. ================================================================================ Installation 1 TekExpress USB2 i. Download deployment package of TekExpress USB2 "TekExpress_USB2_Wrapper_v10.2.5.27_066166804.exe" on the oscilloscope. ii. Close & exit TekScope or any other running application. iii. Run the "TekExpress_USB2_Wrapper_v10.2.5.27_066166804.exe" program and follow the installation wizard to install the application. After the installation is complete select "Restart" to reboot the instrument. iv. After restart of the oscilloscope, Go to Analyze menu to launch TekExpress USB2 application. 2 Tektronix HSETT Controller Service TekExpress USB2 requires High Speed Electrical Test Tool (from USB-IF) to be running on a 3rd party PC, referred to as HSETT PC hereafter. HSETT is used to control the DUT test mode. The Tektronix HSETT Controller Service (referred to as Service, hereafter) runs on HSETT PC and works as a bridge between HSETT and TekExpress USB2. TekExpress USB2 application expects HSETT tool to be running on a remote PC (HSETT PC). 2.1 Pre-requisites for the controller PC/Laptop: i. Windows 7, Windows 10 64-bit OS with at least one USB3.0 port ii. USB-IF supplied xHCI HSETT latest version to be installed 2.2 Installation: i. Use the "TekExpress_USB2_Wrapper_v10.2.5.27_066166804.exe" to install HSETT Controller on the controller PC/Laptop. ii. Follow the installation instructions. iii. Note the IP address of the controller PC to be provide to TekExpress USB2. 2.3 Verifying HSETT Controller installation: i. Ensure that Tektronix HSETT Controller Service appears in Windows Service Manager (using services.msc) or Windows Task Manager. ii. Ensure path C:\Program Files\Tektronix\TekApplication\Tektronix HSETT Controller\ is created. ================================================================================ If for some reason you are unable to download or install this software please contact the Tektronix Technical Support Center: Customers calling within the U.S. call 1-800-833-9200 press 3. Customers calling from outside the U.S. call 503-627-2400. ---End of File---