Version: [1.6.3] Last Revised: [12-Mar-2018] Products: This firmware supports all 5 Series MSO oscilloscopes Version: 1.6.3 (15-Feb-2018) New Features: - Autoset improvements: optimize vertical ADC range, optimize for visibility in overlay mode, provide user-selectable options for what autoset changes, optimize autoset to use trigger source - Power: includes support for Magnetics, Power Efficiency and RDSon measurement and plots - Search Event Table: display search results in table view - Stop acquisition on found search event - Radix specific keypads added for serial bus - Measurements on trend plots - Re-arrange badges in the Results and Settings Bar. Change ordering of waveform slices in stacked mode by changing badge order in Settings Bar. Change measurement table ordering by changing measurement order in Results Bar - Gated save: save regions defined by cursors or screen gating - Floating license: provide support for floating licenses - Inverted screen shot - Sample point highlight: displays sampled acquisition points when waveform style is dot mode and display is interpolating - Enable press and hold for front panel navigation: provides auto repeat of navigation steps on hold - Improved configuration and labelling for digital bits and channels - 5-SEC Power up: when 5-SEC option is installed system no longer restores instrument settings on power up - Updates and improvements to Jitter measurements - Additional bus decode and trigger support for SENT bus Defects Fixed: - ADA400A probe displays wrong attenuation - Resolve 1A (TIVH) probe with 2500x tip causes scopeapp to crash - Rising slew rate measurement requires more than 1 edge on screen - Channel BW filters not working correctly - Attaching TAP1500 probe causes POST to fail - Math FFT does not display custom label - SPI decode found to crash with certain signal inputs with noise on longer record lengths - Roll mode not working correctly in single acquisition mode Known Issues: - Mask files created with oscilloscope firmware version 1.4.x cannot be used in firmware version 1.6.x. Use version 1.6.x and later to create and recall mask files. - TIVH probe offset range not handled correctly when exceeds oscilloscope range limits - Saving large CSV file to USB may fail if USB drive ejected early - Cascading two filters in math expression may not yield expected results - P5205A probe not recognized by 5 Series - When connecting an non-touch external monitor and setting to Extended mode, the oscilliscope touch screen may no longer respond to touch Solution: Open Windows Tablet PC Settings and then select Setup. Follow jinstructions to calibrate Windows for the new configuration - TekScope not operating correctly if switching between Windows accounts Solution: avoid use of Windows fast switch user accounts. Sign out of one account before logging into another user account Version: [1.4.9] Last Revised: [07-Nov-2017] Products: This firmware supports all 5 Series MSO oscilloscopes Version: 1.4.9 (02-Nov-2017) New Features: - The 5 Series MSO oscilloscopes operates with Windows 10 operating system (5-WIN and SUP5-WIN) - Fast Frame : use the Fast Frame control windows to capture and view a series of triggered acquisitions without wasting acquisition memory. - Roll Mode : lets you see acquired data without waiting for the acquisition of a complete waveform record - TekExpress Automotive Ethernet available on Windows 10, 5 Series oscilloscopes - Power : includes support for Power Quality, Harmonics, Switching Loss, SOA, Line Ripple and Switching Ripple measurements and associated plots - Security option : supports ability to ensure secure storage of user data, enable/disable USB devices, Ethernet ports and firmware upgrade/downgrade - Updates and improvements to Jitter measurements - Additional bus decode and trigger support including ARINC429, Mil-Std-1553 and CAN-FD Defects Fixed: - Edge configuration not recalled correctly for skew and phase measurements - Saving screen images too quickly results in the Save Confirmation message appearing in the next image - Parallel bus trigger data value not restored from setup file - File modified time/date value does not match oscilloscope time/date display - TCP0030A Probe range displays incorrection when attempting to change the range while range mode set to Auto - Pressing default setup while TCP0030 probe attached to CH1 changes the trigger unit from A back to V - Save on trigger limited to 100 files - Need to be able to set separate reference levels for same channel when used in delay measurement - Zooming by pan/zoom from a non-zoomed state improvements - Comment text field in Report tab doesn't support pop-up keyboard - Scale ratio not included with saved setups Known Issues: - When connecting an non-touch external monitor and setting to Extended mode, the oscilliscope touch screen may no longer respond to touch Solution: Open Windows Tablet PC Settings and then select Setup. Follow instructions to calibrate Windows for the new configuration - TekScope not operating correctly if switching between Windows accounts Solution: avoid use of Windows fast switch user accounts. Sign out of one account before logging into another user account Version: [1.2.0] Last Revised: [23-Jun-2017] Products: This firmware supports all 5 Series MSO oscilloscopes Version: 1.2.0 (9-Jun-2017) New Features: - The oscilloscope now contains 17 demo sessions that can be recalled from the Utility->Demo menu. These demos operate without the need for probes or signal sources. - The instrument displays a dialog menu informing the user when the internal temperature is approaching a critical juncture. - FFT Phase Wrap can be adjusted beyond 180 degrees - AFG arbitrary waveforms support CSV data format Defects Fixed: - Recalling saved setups now restore window size and position - Miscellaneous settings now restored after recall of saved setups - Notes now restored after power cycle - Certain probe settings now restored after power cycle - Fixes related to installing and removing option licenses - Fixes related to save/recall menu operations - Various crashes involving concurrent time-consuming operations - Jitter measurement summary while acquiring - Corrections to the online help - Recalling setups/sessions when probe configuration has changed - Issue using DVM and frequency counter simultaneously - Math and cursor calculations on peak detect data - Infinite persistence no longer cleared on certain settings changes - Persistence now works on plot data - Various minor issues related to USB bus decode - Various minor issues related to LIN bus decode - Spectrum plot of digital channel data now working correctly - Various corner-case issues with cursors, primarily in plots - Acquisition system error possible on 6-channel models and runt trigger - Save on trigger now indicates operation complete - Save on trigger may terminate prematurely - Various issues related to the programmatic interface - Various issues related to Undo/Redo - Various issues related to Auto Scale on Time Trend waveforms - Graticule scale labels for FFT - Audio bus decode and trigger can become out of sync - The limited bandwidth icon may appear when operating at full bandwidth - Pushing Set to 50% sets vertical position incorrectly if non-zero - Pinch-to-zoom doesn't expand at correct location - Probes with alarm settings may be out of sync with the probe menu - Ethernet bus and search may become out of sync - FFT auto scale doesn't always set horizontal scale correctly - Busy indicator is missing during save setup - XY/XYZ plot labels off by factor of 2 if zoom is on - DVM resolution may show more or less resolution, depending on scale - Fixed limitations on amount of data shown in USB bus tables - Trigger position with SPI bus and SS Active trigger now correct - Flexray trigger no longer limited to 40 Mbps - Cursor gating now works with V Bars (in addition to waveform cursors) - Various issues with Auto Increment File Name count in Save As menu - The number of powerups in the Self Test menu may double-count - Various cosmetic improvements in various menus Version: 1.0.5 (29-May-2017) New Features: - This is the initial release