Date: 30th July, 2016

Product: 40GBase-CR4

Version: v10.0.0

Contents of this Readme File:
1. Introduction
2. Supported list of equipment and accessories
3. 40GBase-CR4 created changes on your system.
4. Before you click "RUN"
5. Recommendations
6. Known Limitations
6.1 Installer related limitation

================================================================================
1. Introduction

The Tektronix 40GBase-CR4 options provide design and validation engineers an easy and fast way to debug and perform compliance testing for CR4 devices

40GBase-CR4 options install:
- '40GBase-CR4' DPOJET Plug-in

The MOI contains the procedure for installation and the detailed information on how to
use the system.

=================================================================================
2. Supported list of equipment and accessories

All MSO/DPO/DSA70K C/D/DX/SX series with Bandwidth 16GHz & above

Minimum recommended Requirement:
TekScope:
WIN7 Ver :10.3.0 and above

DPOJET:
Ver.10.0.0 and above
=================================================================================

3. 40GBase-CR4 created changes on your system
40GBase-CR4, a DPOJET Plug-in
a) CR4 can be launched from “40GBase-CR4“ menu under “Analyze” menu of Scope application menu
b) Launching CR4 option from Analyze menu of TekScope will launch DPOJET application with “40GBase-CR4” selected under Standards tab.
c) 40GBase-CR4 Essentials measurements on DPOJET do not have dedicated free trials.

=================================================================================
4. Before you click "RUN"

a) Ensure that all the required instruments are properly warmed up, Signal Path Compensation (SPC) is performed & channels are deskewed
b) It is highly recommended to read 40GBase-CR4 MOI before you click "RUN
c) Ensure that the following softwares are installed in your system.
Tekscope (v10.3.0 onwards on Win 7 scope)
DPOJET (v10.0.0 onwards on Win 7 scope)
Adobe Reader 6.0 or equivalent software for viewing portable document format (PDF) files

=================================================================================
5. Recommendations

Following recommendation to avoid any issues while running the tests

a) Please acquire atleast 5M record length for all measurements. Otherwise results may not be correct.

=================================================================================
6. Known Limitations

6.1 Installer related limitation
a) Required softwares are installed on C:\ only.
b) User needs to have administrative privilege while installing the application
c) If DPOJET software is upgraded and/or for some reason the DPOJET software is uninstalled and then re-installed, please re-install 40GBase-CR4 software.

6.2 40GBase-CR4 option related limitation
a) User needs to have administrative privilege while running the tests.

================================================================================================