1. Introduction

The Tektronix FC-16G DPOJET Essential Option provides engineers an easy and fast way to debug and perform compliance testing for FC-16G Tx devices.

FC-16G option supports:
- FC-16G DPOJET Plug-in

The MOI contains the procedure for installation and the detailed information on how to
use the system. The MOI is located at C:\Program Files\TekApplications\DPOJET\FC-16G Essentials MOI.pdf.

=================================================================================
2. Supported list of equipment and accessories

All MSO/DPO/DSA70K C/D/DX/SX series with Bandwidth 20GHz & above

Minimum recommended Requirement:
TekScope:
WIN7 Ver :10.3.0 and above

DPOJET:
Ver.10.0.0 and above

=================================================================================
3. FC-16G created changes on your system

FC-16G Option, a DPOJET Plug-in
a) FC-16G can be launched from “FibreChannel-16G" menu under “Analyze” menu of Scope application menu
b) Launching FC-16G option from Analyze menu will launch DPOJET application with the technology FC-16G selected. The dropdown will have FC-16G enabled only if the FC-16G option is enabled on the scope.
c) FC-16G measurements on DPOJET do not have free trials.

=================================================================================
4. Before you click "RUN"

a) Ensure that all the required instruments are properly warmed up, Signal Path Compensation (SPC) is performed & channels are deskewed
b) It is highly recommended to read FC-16G MOI before you click "RUN".
c) Ensure that the following software is installed in your system.
Tekscope (v10.3.0 onwards on Win 7 scope)
DPOJET (v10.0.0 onwards on Win 7 scope)
Adobe Reader 6.0 or equivalent software for viewing portable document format (PDF) files

=================================================================================
5. Recommendations

Following recommendation to avoid any issues while running the tests

a) Please acquire atleast 5M record length for all measurements. Otherwise results may not be correct.

=================================================================================

6. Known Limitations in evaluation version

6.1 Installer related limitation
a) Required software is installed on C: only.
b) User needs to have administrative privilege while installing the application.
c) If DPOJET software is upgraded and/or for some reason the DPOJET software is uninstalled and then re-installed, please re-install FC-16G software.

6.2 FC-16G option related limitation
a) User needs to have administrative privilege while running the tests.

=================================================================================