Manufacturer: Keithley
Supported Language(s): LabVIEW 2015 and newer. Tested with both 32 and 64 bit versions of LabVIEW. Not tested with LabVIEW NXG
Supported Model(s): 2450, 2450-NFP, 2460, 2461, 2470
Model(s) Tested: 2450, 2460, 2461, 2470
Interface(s): GPIB, USB, LAN(VXI-11)
Firmware Revision(s) Tested:1.6.7c (for 2450, 2460, 2461) and 1.6.8d (for 2470)
NI Supported: No
Keithley Supported: Yes
Original Release Date: 8/14/2013
Current Revision Date: 5/15/2019
VISA 3.2 or later
Refer to the LabVIEW Help for more information about software
requirements. You access the LabVIEW Help by selecting Help»Search the LabVIEW Help.
Original Release
REV 1.1.1.0 8/26/2013
PR50553:
Set IO Pins vi was removed. Functionality available in
Write to all Digital IO Pins vi.
PR50554:
Configure Limit Test Settings vi removed from driver
as command no longer supported.
PR50555:
Updated Configure Linear Step Mode Sweep vi default
values for start, stop and step. Also updated documentation for step control to
clarify this is for voltage/current step and not the amount of steps in the
sweep.
PR50556:
Configure Log Mode Sweep vi has been updated with
default Start value of 0.1 instead of 0 to prevent asymptote issue.
PR50557:
Configure Measurement Auto Range Lower Limit vi has
updated its Manual Range control default value to 0.1.
PR50558:
Added Configure Measurement Auto Range Upper Limit vi.
PR50559:
The Configure Reading Format of Display vi had the
AUTO option removed as it is not supported.
PR50560:
Configure Trigger Model Constant Delay Block vi has
the Delay in seconds control updated from 1us to 50us.
PR50561:
The Load Trigger Model Configuration List vi has a
SCPI syntax error that has been resolved.
PR50562:
The Abort vi had SCPI syntax error that is now
resolved.
PR50563:
The Beeper Enable vi was removed from the driver as
that command is no longer supported.
PR50564:
The Get Display Screen vi was removed as it is no
longer supported.
REV 1.1.2.0 1/26/2014
PR50747:
Renamed the Resistance measurement function to Auto Resistance. Added a Manual Resistance measurement function.
PR50947:
Palette files for LabVIEW version 8 have been repaired.
REV 1.2.0.0 09/08/2014
Added model support for 2460 series Instruments.
Help content updated for several VIs and Controls.
REV 1.3.0.0 01/27/2016
Added model support for 2461 series Instruments.
Help content updated for several VIs and Controls.
REV 1.4.0.0 05/15/2019
Added model support for 2470 series Instruments.
Help content updated for several VIs and Controls.
New VI added : Configure Voltage Breakdown Protection.vi