README.TXT for TekExpress MHL Ver.10.0.1

Contents:
1. Introduction
2. Before you click "RUN"
3. TekExpress MHL created changes on your system.
4. Supported Tests
5. Supported list of equipment and accessories
6. Known Limitations
6.1 Installer related limitation
6.2 TekExpress application related limitation
6.3 TekExpress application known issues

============================================================================================
1. Introduction

The Tektronix TekExpress MHL is an automated test solution for testing the MHL compliance
for Physical Layer Solution of MHL DUTs as per CTS 1.2, CTS 2.0, CTS1.3/2.1 & CTS 3.3

============================================================================================
2. Before you click "RUN"
a) Ensure that all the required instruments are properly warmed up, Signal Path Compensation
(SPC) is performed, followed by calibration and cable deskew.
b) Steps for network drive connection
b.1) Background information : After you first launch TekExpress, it creates the following
folders on your computer:

"\My Documents\My TekExpress"

NOTE. Ensure that the "My TekExpress" folder has Full read and write access.
NOTE. If a user with a different Windows login ID launches TekExpress,
a new folder is created under "My documents" of new user.

"\My Documents\My TekExpress\MHL"
"\My Documents\My TekExpress\MHL\Untitled Session",

this sub-folder is created every time the "TekExpress MHL.exe" is launched and this
sub-folder is deleted when you exit application.

CAUTION: Each session has multiple files associated with it. Do not modify any of the
session files and/or folders as this may result in loss of data or corrupted
session files.

The "My TekExpress" folder mentioned above is created as a shared folder
with share name as ?s My TekExpress

============================================================================================
3. TekExpress MHL created changes on your system.
After first launch of "TekExpress MHL.exe" following changes take place in your
computer.
a) "My TekExpress" folder is created under "My Documents" folder of current user
NOTE: If a user with new login ID launches "TekExpress MHL.exe",
"My TekExpress" folder is created under "My Documents" of the new user.
b) "MHL" folder is created under "My TekExpress" folder
c) "Untitled Session" folder is created under "MHL" folder, note that
every time "TekExpress MHL.exe" is launched "Untitled Session" folder is
created under "MHL" folder and will be deleted after proper termination
of application.
d) If user saves a session in TekExpress MHL all session files are saved under "MHL" folder.
Note that each session has multiple files associated with it and do not tamper with any
of the session file(s) and/or folder(s) this may result in loss of data or corrupted
session files.
============================================================================================
4. Supported Tests
MHL Compliance supports All transmitter, Receiver & Cable tests for Physical Layer
Solution in this version of the application.

a) MHL1.2 / 1.3 Receiver solution supports three resolution 25 MHz,27 MHz and 74.25 MHz
b) MHL2.0 / 2.1 Receiver solution supports four data rates 2.97Gb/s, 2.22Gb/s 0.81Gb/s &
0.75Gb/s
c) MHL3.3 Receiver solution supports 6Gb/s, 3Gb/s, 1.5Gb/s

============================================================================================
5. Supported list of equipment, accessories and software

Supported scopes for MHL 3.3
Tektronix DPO/DSA/MSO70000/D/DX/SX with BW 12.5G and above.

Supported scopes for MHL 1.2 / 2.0 / 1.3 / 2.1
Tektronix DPO/DSA/MSO70000/D/DX/SX with BW 8G and above.

For MHL 1.2 / 2.0 / 1.3 / 2.1 / 3.3
Minimum Requirement: Two P7313SMA probes and one P7240 probe

TekScope:
WiN7 Ver: 10.3.0 & above (For DPO/DSA/MSO C, D, DX & SX Series only)

DPOJET:
Ver. 10.0.0 & above (Win7)
============================================================================================
6. Known Limitations

6.1 Installer related limitation
a) Installation of TekExpress and other software packages are installed on C: drive only.
b) The available free space on C: drive must be minimum 2.2GB.

6.2 TekExpress application related limitations
a) Tests will be started only when all the instruments are available.
b) The application is best viewed in super VGA resolution or higher video adapter
(800x600 minimum video resolutions for small fonts or 1024x768 minimum video
resolutions for large fonts) with 96 dpi display settings. If application is
running on instrument with lower resolution then it is recommended to use
secondary monitor.
d) During test execution if user pause the execution and if user does any changes
in instrument setup, then it is important that user restores the instruments
settings to same state before clicking "Continue".
e) Need to have sufficient hard disc space (Minimum of 2GB) to save the session
information.

6.3 TekExpress application Known issue
a) None

============================================================================================