Date : Mar-2016
Product: TDSUSB2 (USB2.0 Compliance Test Package)
Version: 4.0.0

===========================================================
What is in this Readme File:

1. System Requirements
2. Contents of Distribution
3. New features
4. Known Limitations
5. Installation
6. Contact Information

===========================================================

1. System Requirements

- Note that the best MS Windows(TM) task bar settings for
running this application are:
Always on top = unchecked
Auto Hide = unchecked

- The TDSUSB2 Application is targeted towards TDS5000/B,TDS6000/B/C,
TDS7000/B,CSA7000/B,DPO5000,DPO7000,DPO/DSA70000/B/C/D,MSO5000 and MSO70000 series oscilloscopes.

- Sun Microsystem's Java Runtime Environment (JRE) version 1.4.2_02 is
required for this release. If you are not sure about your JRE version,
please uninstall your JRE before installing the application. The proper
version of the JRE will be automatically installed when USB2 is installed.
If the JRE is deleted for some reason, then re-install USB2.
This is available on the Optional Applications Software compact disc.

- The use of a keyboard and a mouse is recommended. For all file-based
usage, these are required.

- The latest firmware version of Oscilloscope needs to be updated prior to
updating TDSUSB2.

- The latest version of the software can be downloaded from the
Tektronix website at http://www.tektronix.com. Click on the
"Software & Drivers" link on the right side of the screen.

- The High Speed option is enabled on oscilloscopes which have 2.5 GHz
or higher bandwidth

- Disk space requirements:

55Mb of free disk space to install and operate this application

===========================================================

2. Contents of Distribution for x86 architecture

Directory listing of C:\Program Files\TekApplications\TDSUSB2

checkOS.txt
Device~1.PDF
Host~1.PDF
Hub~1.PDF
INSTGP~1.DLL
Readme.txt
RF~1.txt
SRM.XML
SRMx86.XML
STARTH~1.BAT
TDSUSB2.BAT
TDSUSB2.CHM
TDSUSB2.JAR
TDSUSB2.PDF
TDSUSB2Q~1.pdf
TDSUSB2~b.c
INSTGP~1.DLL
Version.txt

Directory listing of C:\TekApplications\tdsusb2\tsvfiles

Inrush.TSV
HS_SQC.TSV
FS_SQC.TSV
LS_SQC.TSV

Directory listing of C:\TekApplications\tdsusb2\datagen

MIN-ADD1.PDA
INADDR1.PDA
IN-ADD1.dtg
MIN-ADD1.dtg

Directory listing of C:\TekApplications\tdsusb2\tsvfilegenerator

DPLUS.CSV
DMINUS.CSV

Directory listing of C:\TekApplications\TDSUSB2\Mask

HS_SQC.MSK
-----------------------------------------------------------
Contents of Distribution for x64 architecture with Win7 OS

Directory listing of C:\Program Files (x86)\TekApplications\TDSUSB2

checkOS.txt
Device~1.PDF
Host~1.PDF
Hub~1.PDF
INSTGP~1.DLL
Readme.txt
RF~1.txt
SRM.XML
SRMx86.XML
STARTH~1.BAT
TDSUSB2.BAT
TDSUSB2.CHM
TDSUSB2.JAR
TDSUSB2.PDF
TDSUSB2Q~1.pdf
TDSUSB2~b.c
INSTGP~1.DLL
Version.txt

Directory listing of C:\Users\Public\Tektronix\TekApplications\TDSUSB2\tsvfiles

Inrush.TSV
HS_SQC.TSV
FS_SQC.TSV
LS_SQC.TSV

Directory listing of C:\Users\Public\Tektronix\TekApplications\TDSUSB2\datagen

MIN-ADD1.PDA
INADDR1.PDA
IN-ADD1.dtg
MIN-ADD1.dtg

Directory listing of C:\Users\Public\Tektronix\TekApplications\TDSUSB2\tsvfilegenerator

DPLUS.CSV
DMINUS.CSV

Directory listing of C:\Users\Public\Tektronix\TekApplications\TDSUSB2\Mask

HS_SQC.MSK
===========================================================
3.New features



Features in version 4.0.0
* Installer Changes to make application 'Tek-Audit' compatible.
* Enhancement to "eye height measurement".
* Changed threshold for Device chirp measurement.

-------------------------------------------------------------
Features in version 3.9.3
* Custom Mask support(.msk) for High Speed signals.
-Only symmetric masks are supported.
-Mask coordinates must be written in .msk file in the following order.

(2)____(3)
/ \
(1) / \(4)
\ /
(6)\____/(5)

* Packet parameter tests now shows results in both bits and time.
* Rise Time and Fall Time limits are changed as per the modified USB-IF Compliance update with subject"New Rise and Fall Time Parameters for High-speed Signaling" (ID 87)

-------------------------------------------------------------
Features in version 3.9.2

* Improved High Speed Packet Parameter measurement algorithm
* Fixed issues related to Save/Recall capability through PI.
* Improved Suspend and Reset from High-speed measurements
* Added capability to generate .tsv files for Single Ended HS SQC measurements. 2 files are generated – 1 with single ended sources and 1 with differential source
* Enhanced the UI for Inrush measurement

-------------------------------------------------------------
Features in version 3.9.1

* Installation Errors in Windows2000 on TDS Scope is fixed
-------------------------------------------------------------
Features in version 3.9.0

* Single Ended Probe support for HS SQC measurements
* Improvements in inrush measurement - added user configurable Vertical parameters for
inrush measurements i.e, Verticle scale, Trigger Level and Sequence type.
* Fixed issues related to HS EOP width and HS Resume SOF Amplitude

-------------------------------------------------------------

Features in version 3.8.0

* Folder structure has been changed to adhere to Win7 guidelines.
The new folder structure is applicable only for Win7 PCs with x64 bit architecture
The following table lists the new folder structure

Folder Name Current Location Moves to
images C:\TekApplications\TDSUSB2\images C:\Users\\Tektronix\TekApplications\TDSUSB2\images
report C:\TekApplications\TDSUSB2\report C:\Users\\Tektronix\TekApplications\TDSUSB2\report
setup C:\TekApplications\TDSUSB2\setup C:\Users\\Tektronix\TekApplications\TDSUSB2\setup
datagen C:\TekApplications\TDSUSB2\datagen C:\Users\Public\Tektronix\TekApplications\TDSUSB2\datagen
tsvfilegenerator C:\TekApplications\TDSUSB2\tsvfilegenerator C:\Users\Public\Tektronix\TekApplications\TDSUSB2\tsvfilegenerator
tsvfiles C:\TekApplications\TDSUSB2\tsvfiles C:\Users\Public\Tektronix\TekApplications\TDSUSB2\tsvfiles

* Fixed issues related to EyeDiagram Waiver for Conditional Pass.
* Corrected the range for High Speed Chirp Measurement

-----------------------------------------------------------

Features in version 3.7.0

* Improvements in Host Packet parameter measurement, signal rate measurement and host chirp EL_35 measurement.
* Support for DPO/MSO5034,5054,5104 and 5204 oscilloscopes.

------------------------------------------------------------
Features in version 3.5.0

* For FS and LS SQC measurements, the reporting of rising and falling edge rates are removed from the
summary, details and reports panel.
* The waiver limits for Inrush current measurement changed according to the latest USBET(version 2.30.00).
* Scope settings changed for host chirp EL_35.
* Fixed issues related to trigger, interpacket gap and sync field in Packet parameter measurement.
* Support for MSO series Oscilloscopes.

-------------------------------------------------
Features in version 3.4.0

* User bandwidth limit support for HS and FS SQC measurements
* Inrush region calculated only till 100ms
* Added PI support to check for confirm waveform message dialog for SQC measurements

-------------------------------------------------

Features in version 3.3.0

* Support for DPO/DSA B series Oscilloscopes
* Fix for resume measurement amplitude problem

-------------------------------------------------
Features in version 3.2.0

* Inrush Current Measurement modified according to the latest USBET (Version 2.22.03)
Algorithm for Analyzing Inrush Current.
* Monotonic Property Measurement excluded from calculating overall pass/fail results for High-Speed Signal Quality Tests.
* User-defined bandwidth scope settings retained.
* Resume Time calculation issue fixed.
* Full-Speed Signal quality Sample rate updated to 4GS/s as recommended by USB-IF (version 2.22)

-------------------------------------------------
Features in version 3.1.1

* Checks for Non Symmetrical D+D- Waveforms for Rising/Falling Edge Rate Measurements.
* Check for Upper Limit for HS Rising/Falling Edge Rate Measurements.

-------------------------------------------------
Features in version 3.1.0

* Support for Rising and Falling Edge Rate measurement for High Speed, Full Speed and Low Speed.
* Fixed Issues related to zero Jitter Values, for Full speed Jitter measurements.
* Conditional PASS of waiver when the Squelch value is between 100mV from 50mV.
* Warning message related to inrush measurement threshold level

-------------------------------------------------
Features in version 3.0.8

* Fix for RT/FT warning issue
* Fix for LS jitter issue
-------------------------------------------------
Features in version 3.0.7

* No Customer features beyond 3.0.6

-------------------------------------------------

Features in version 3.0.6

* Vertical autoscaling

* RGPIB control to query results

-------------------------------------------------
Features in version 3.0.5

* Changes in Resume measurement
* Fix for HS Tier1 plug fest report
-------------------------------------------------
Features in version 3.0.4

* Remote GPIB Support for controlling the application remotely
-------------------------------------------------
Features in version 3.0.3

* Support for DPO/DSA70404,DPO/DSA70604 and DPO/DSA70804 Oscilloscopes
* Compliance with the new Intel Matlab scripts
-------------------------------------------------
Features in version 3.0.0

* Support for DPO7054,DPO7104 and DPO7254 Oscilloscopes
* The problem of deskew value getting reset each time the measurement is run
is fixed
* Support for ICH6 chipsets which have < 1.2uS time intervals

-------------------------------------------------
Features in version 1.9.1

* No customer features beyond version 1.9.0

-------------------------------------------------
Features in version 1.9.0

* Support for TDS6124C and TDS6154C Oscilloscopes
-------------------------------------------------
Features in version 1.8.0

* Support for TDS6604B and TDS6804B Oscilloscopes

-------------------------------------------------

Features in version 1.7.1

* ?Select All? feature for the selection of all Signal Quality(SQ)measurements

* Support for the following new HS measurements Suspend,Resume,Reset from
High-Speed,Reset from Suspend and Packet Parameter

* Packet Parameter test can be configured for Host(EL_21,EL_23,EL_25;EL_22
and EL_55) and Device(EL_21,EL_22,EL_25 and EL_22)

* Chirp Measurement has separate tests for Host(EL_33,EL_34 and EL_35) and
Device(EL_28,EL_29,EL_31)

* The Application supports TDS5034B, TDS5054B and TDS5104B oscilloscope

* Support for device id input before automatically generating report or data
files

* Support for automatic data file(TSV) generation

* CMD and Diff in saved jpg file of pulse diagram has interchanged

* In Preferences panel waiver mask information text has been rephrased

* Receiver Sensitivity configuration parameters is moved to a panel,instead
of the earlier way of popping up a dialog box

* The results obtained upon running the new measurements (Reset from High
Speed,Reset from Suspend, Resume, Suspend and Packet Parameter) are put
in a report

* Sun Microsystem's Java Runtime Environment (JRE) version 1.4.2_02 is
supported for this release

-------------------------------------------------

Features in version 1.6.0

* No customer features beyond version 1.4.0

-------------------------------------------------

Features in version 1.4.0

* Full Speed Eye geometry has changed according to current USBIF procedures

* Waiver eye mask for full speed measurement is removed

* Waiver in eye mask introduced for High speed

* No waiver mask for High speed Far End testing

* In Full Speed measurement, Rise time and Fall time are not a pass/fail
criteria

* For Rise Time and Fall Time,additional information is provided

* There is a version number of the TDSUSB2 software in the generated report

* Qualified on Windows2000 (TM) Professional Operating System and backward
compatible with Windows98 (TM) and WindowsME (TM) OS

* Log files for Window2000 are in a different location than
Windows98/WindowsMe:Win2K (TM) log files are deposited in
C:\Documents and Settings\Windows98/WindowsME log files are
deposited in C:\WINDOWS

* Added Start menu shortcuts for OLH and the PDF
Start > Programs> TekApplications> TDSUSB2> Help (PDF Version)
Start > Programs> TekApplications> TDSUSB2> Help

-------------------------------------------------

Features in version 1.3.0

* No customer features beyond version 1.2.0
-------------------------------------------------

Features in version 1.2.0

* Eye Violation is reflected in Pulse Diagram (Waveform plot)

* Report Generation support for Chirp and Receiver Sensitivity

* The unused channels for selected measurements are switched off

* Hysteresis Band of 10 mV provided for Monotonic Signal to limit the
effect of noise on the signal

* EOP data for High Speed Test displayed in bits as well as in seconds

* Additional information for Jitter added to result and report for High
Speed Test

* The result of Chirp-K Amplitude measurement displayed in Additional
Information button in summary and detailed results and report. The
displayed result contains only the measured value of the Chirp-K
Amplitude and the nominal value specified by USB-IF. The Chirp-K
Amplitude test is for information only and not a PASS/FAIL criteria

* The Receiver Sensitivity and Squelch are measured using the positive
and negative peak values separately instead of the peak to peak values of
the DG2040 signal

* EL_15 test renamed to EL_18 as per the revised USB-IF test procedure

* In EL_18 test, manual selection of "Response" or "No Response" state is
possible

* Overall Result of Receiver Sensitivity Analysis is calculated depending
on the individual result of Receiver Sensitivity, Squelch, EL_18 and the
difference between the receiver sensitivity and the squelch values

* For Rise Time and Fall Time measurements, warning is displayed when
calculated Rise Time and Fall Time values are greater than 1 bit time of
the signal

-------------------------------------------------

Features in version 1.1.0

* Fully compliant with USB-IF tests for USB2.0 compliance testing

* Automated eye diagram analysis

* Automated oscilloscope setups

* High Speed specific tests: Receiver sensitivity, Chirp and Monotonicity
test

* Automatic Rise and Fall time measurements

* Automatic Deskew for accurate measurements

* User selectable report formats (Tek Format, Plug fest Format and CSV Format)

* User configurable measurement limits for tolerance testing
===========================================================

4. Known Limitations

* The setup files saved in the prior versions of TDSUSB2.0 will be incompatible
for this new version. Recalling an incompatible file will show an error
message and the default set up will be recalled.


* The Hide button does not bring the instrument application to full screen.
Clicking anywhere in instrument Application will achieve this.

* Some of the Windows of application (for example, preferences panel) will go
behind the application window and cannot be brought to the front for proper
operation. Restart the application/oscilloscope to overcome this problem.

* Press the ENTER key to ensure proper selection of a file. For example,
in Utilities->TSV File Generator after entering the TSV file name,
press ENTER to commit changes

* This application uses Java's printing capabilities and depends on the operating
system for most of its operation. If no printer is connected to the
oscilloscope, then there may not be any error message from the operating
system. Ensure a printer is connected and working properly before using
printing feature in application

* For Inrush and Droop measurements, the report does not include any images.

* The HIDE and CLOSE button can intermittently remain in the foreground
when the TekScope application goes full window and displays the "App"
button. If this occurs, click anywhere in the TekScope Application to bring
the TekScope application forward.

* When attaching a secondary monitor, set the color setting to a higher
color depth than 256 colors to be the same as the primary monitor. The
application will fail to invoke with a secondary monitor color setting of
256 colors or less.

* Administrator privileges are required to install or uninstall the TDSUSB2
application on Windows 2000 and XP operating systems. If you do not have
administrator privileges, contact your system administrator to
install the application.

===========================================================


5. Installation

Normally, the TDSUSB2 application resides on the hard drive of
your oscilloscope. If the application is not installed on hard disk,
perform the following steps to install the application from
the Optional Applications Software on a Windows-based Oscilloscope
compact disc (CD or DVD):

1. If the keyboard is not installed, connect it to the oscilloscope rear
panel (the optional-accessory keyboard plugs into the USB connector)

2. Power on the oscilloscope to start Windows

3. Insert the optional applications software DVD in the CD or DVD drive
of the oscilloscope

4. The autorun utility will start the installation program

5. Select the option 'USB 2.0 Test package'

6. Select the option 'INSTALL NOW'

7. Follow the instructions given by the InstallShield Wizard. If Java
Run-time Environment (JRE 1.4.2_02) software is not previously installed,
then the InstallShield Wizard will prompt for installing it. Click
"Yes" when prompted for installing JRE 1.4.2_02 and the InstallShield
will install it. Do not change the default locations to install
the files. The oscilloscope must reboot to complete the installation process.

8. You will need to enter the authorized Option Installation Key to enable
the application. The key is specific to the serialized oscilloscope and
options for which it was purchased. Do not enter this key until all
application software that you have purchased has been installed. To
enter the key number, follow these steps:

a. If the oscilloscope is powered on and in the toolbar mode (default),
select the Menu button (upper right corner of the display) to put
the oscilloscope into menu-bar mode. In menu-bar mode you should
see a PC-style menu across the top of the display.
b. Go to the Utilities menu in the menu bar and select Option
Installation.
c. Follow the on-screen instructions to enter the alphanumeric key
number exactly as it is printed on the rear-panel label.

NOTE:
If the autorun utility fails to start in step 4, then select the My Computer icon.
In the Exploring My Computer window, select the drive letter associated with the
CD or DVD (for example, D:) drive. Select the file LAUNCH.EXE to start the
installation program. Complete the installation process by performing steps
5 to 8 as mentioned above.

The TDSUSB2 application is now ready for use. Start the application by
using ANALYZE->USB2.0 Test Package menu selection on the oscilloscope menu.
To restore the application, when hidden or minimized, click on the ANALYZE->RESTORE
button.


===========================================================

6. Contact Information

-- Telephone:

Contact your local Tektronix Representative at 1-800-833-9200
Sales support select option 1
Service support select option 2
Technical support select option 3

-- WEB:

http://www2.tek.com/wwwcontact/plsql/Contact.Us

---End of File---