Installation Instructions for the BERTScope Multi-Protocol Receiver Test Automation Software Product: BERTScope Multi-Protocol Receiver Testing for USB3.1 Version: 2.3.0 Date: Feb-2018 Installation Instructions ================================================================================ Minimum System Requirements Processor Pentium 4/M or equivalent processor. Operating System Windows 7 (64-Bit & 32-Bit) or Windows 10 (64-Bit & 32-Bit) Software • Microsoft .NET 4.0 or later • Microsoft Internet Explorer 6.0 SP1 or later (or equivalent) • Microsoft compatible mouse or compatible pointing device. • TCP/IP connectivity. ================================================================================ Download the BERT_Scope_Rx package and extract the application installers This package contains installers for the 1. BERTScope Receiver Test application for USB3.1 Gen1 and USB3.1 Gen2 2. SigTest Server 3. Visa Socket Gateway 4. SigTest for USB3.1 Gen1 5. SigTest for USB3.1 Gen2 6. Switch Control Software ================================================================================ Install the BERTScope Receiver Test Application 1. Copy the BERT_Scope_Rx_20_V2.3.0.X.exe to the desktop of the target computer. 2. If Bert Scope Receiver Test Application V2.0.0 / V2.1.0 / V2.2.0 is already installed in your system; delete the file ‘MasterDefault_USB30.pref’ from the path “C:\ProgramData\Tektronix\BERTScope\RxTest20\USB3.0\ Database_Folder” and delete the file ‘MasterDefault_USB31.pref’ from the path “C:\ProgramData\Tektronix\BERTScope\RxTest20\USB3.1\Database_Folder”. Note: ‘C:\Program_Data’ is a hidden folder, you need to select ‘view hidden folders and files’ for ‘C:\Program_Data’ folder to be visible. 3. Double-click the BERT_Scope_Rx_20_V2.3.0.X.exe executable to run the installer program. 4. During the installation, you will be asked if Microsoft Access 2007 runtime should be installed. Answer yes if there is no version of Microsoft Access 2007 running on your computer. 5. The installation will create a link to the executable program in the Start menu. ================================================================================ Install the VISA Socket Gateway, SigTest Server and SigTest 1. These programs are intended for use with BERTScope Multi-Protocol Receiver Testing application and only for installation on a Tektronix 70000 series real-time oscilloscope. 2. Once you install the BERT Rx application software on your system, you can find a folder with name "Oscilloscope-Installers" in the location "C:\Program Files\Tektronix\BERTScope\RxTest20\Tools". Install SigTestServer_1.18 using the 'TekSigTest_v1.0.1.1.exe' and Visa Socket Gateway using the 'Setup_VisaSocketGateway_1_12_1907.exe' on the Real Time Oscilloscope 3. Once you install the BERT Rx application software on your system, you can find a folder with name "SigTest-Installers" in the location "C:\Program Files\Tektronix\BERTScope\RxTest20\Tools". Install 'SigTest_3.2.11.3.msi' for USB3.1 Gen1 and 'SigTest_4.0.23.2.msi' for USB3.1 Gen2 on the Real Time Oscilloscope. 4. The firewall on the oscilloscope must be opened for these programs. Use the Windows Firewall control panel application to select all traffic associated with these programs to go through the firewall. Alternately you can select only the Port number specified on the main view (Default ports are 4005 for Visa Socket Gateway and 4006 for SigTest Server). ================================================================================ Install the Switch Control Software 1. This program is intended for use with BERTScope Multi-Protocol Receiver Testing application and only for installation on a BERTScope 2. Once you install the BERT Rx application software on your system, you can find a folder with name "BERTScope-Installer" in the location "C:\Program Files\Tektronix\BERTScope\RxTest20\Tools". Install the switch control software using 'Setup_SwitchControl_2_0_1_1886.exe' on the BERTScope. 3. Double-click the file to run the installer program. 4. The firewall on the BERTScope must be opened for this program. Use the Windows Firewall control panel application to select all traffic associated with these programs to go through the firewall. Alternately you can select only the Port number specified on the main view (Default ports are 4003 for Switch Control software). ================================================================================ If you are unable to download or install this software, please contact the Tektronix Technical Support Center: Customers calling within the U.S. call 1-800-833-9200 press 3. Customers calling from outside the U.S. call 503-627-2400.