??Customer Release Notes for Version 10.5.3 Firmware for the DPO7000C

Series Instruments



Versions: 10.5.3

Last Revised: December 22, 2016

Compatible Products: DPO7054C, DPO7104C, DPO7254C, DPO7354C



Software Description

--------------------

This firmware version is for scopes running Microsoft Windows 7 (64-bit).

It includes the following updates:

- Support for service and manufactoring to increase yield

It contains general bug fixes, and resolves the following customer-reported

issues:

- TPP probe compensation fails on MSO/DPO5000-series scopes

- TCP0030/A series probes' vertical scale Range selection is incorrect

for MSO/DPO5000-series scopes



Installation Notes

------------------

- This firmware version is not intended for products running Windows

XP, i.e. DPO7000 products.

- Version 10.5.3 is intended for all other scope models shown in the

Compatible Products list above.

- An all in one  deployment package is available for download,

which contains this new firmware and updated optional

applications. This  deployment package significantly

simplifies the installation of new software. With this

package, you can perform one download and ensure that you

have all the latest software for your scopes. The

installation of the deployment package takes about 30-45

minutes and must not be interrupted until it has completed

the installation of all software.



Initial Turn-on for Standalone Instruments

------------------------------------------

After receipt of a new oscilloscope or the installation of a new

release of software, to ensure peak oscilloscope performance, run Signal

Path Compensation (SPC) after the recommended warm up time has passed.

The SPC item is located in the Utilities menu listed as Instrument

Calibration....



All probes should also be re-calibrated - see Vertical -> Probe Cal...



When a new release of instrument software is installed, some

application software packages must also be updated and installed

separately by the user. If you install the deployment package, the

latest version of applications will be installed with the firmware.



This release supports English only in the scope's graphical user

interface (GUI).



Main Oscilloscope Application

-----------------------------

The main oscilloscope application is critical to the operation of

the instrument as an oscilloscope or as a PC. The application is

expected to be running at all times. Even when minimized on the

Windows taskbar, oscilloscope error messages, notifiers, etc. are

always posted to the desktop. The only time you should exit the main

oscilloscope application is to install other software packages.



Activating Options

------------------

Some options such as extended memory or advanced analysis and

application software are factory installed. If you ordered these

options from the factory, they are already enabled and ready for

you to use.



If you would like to upgrade your oscilloscope to include one of

these options, contact your local Tektronix representative. Once

the purchase transaction is complete, you will be given a new

Option Installation Key that you can enter to enable the desired

options. Refer to the Option documentation for detailed

instructions.



Reverting to an Earlier Version of Firmware

------------------------------------------------------------------------

Reverting to a version of scope firmware earlier than V10.3.3 first

requires a system restore operation, which will re-install the

firmware version originally shipped with the instrument.

Customers can then download the most-recent prior version of firmware

from the Tektronix web site at http://www.tek.com/downloads.



Setting Trigger Level to 50%

----------------------------

Occasionally, getting the proper trigger edge placement may

require more than one press of the Set to 50% button.



Saving and Recalling Bus Channel Threshold Values

-------------------------------------------------

Recalling a system setup file that contains non-default bus channel

threshold values may not restore the expected threshold values. It is

more likely to happen after restoring different system setup files,

mixed with defaulting the system setup. The correct values can be set

through either the GUI or the remote programmable interface (PI).



A-B Seq Trigger Reset Timer

---------------------------

The Trigger Reset Timer may default back to 1 Msec upon

selecting the Select Trigger -> A-B Seq Tab.



Envelope or Average Mode with Line Trigger

------------------------------------------

To ensure proper waveform display when using Envelope or

Average acquisition mode with Line trigger source, turn off

Enhanced Triggering in the Trigger Setup control panel.



LRN Command

-----------

Rather than use the LRN command to restore factory settings, recall

a default setup instead.



Windows Clipboard Limitations

-----------------------------

The size of waveforms copied to the clipboard when using the

Edit->Copy or Ctrl-C key is limited to the size of the Windows

clipboard. Therefore, waveforms with a large record length will

not fit on the clipboard. A notifier will warn you in this case.

The size of the clipboard is determined by the Windows operating

system. File Export is recommended for transferring large

waveform records.



Windows Access Control Limitations

----------------------------------

LXI operation requires specific User Account Control (UAC) settings to work

properly because it needs access control to change the network parameter

configuration. To change the user account settings select

Start -> Control Panel. Then, click on User Accounts followed by

Change User Account Settings. Change the settings to either Never Notify

or Notify me only when programs try to make changes to my computer.



PC Hardware and Software Compatibility

--------------------------------------

DPO series oscilloscopes are sophisticated, highly integrated

hardware and software systems. The oscilloscope is dependent on

the specific version of the PC motherboard and Windows operating

system installed at the factory. Any changes to any of the PC hardware

or the Windows operating system will affect the performance of the

instrument. Do not attempt to modify or update any of the PC

hardware, Windows 7 operating system components, or BIOS settings

unless instructed to do so by Tektronix.



Power Configuration & Settings

------------------------------

Tektronix recommends that you not modify the power-related settings

in either the BIOS or the Power Management areas of Windows 7. They

are set at the factory to a configuration that is optimal for the

instrument. Changing these settings can prevent the oscilloscope

from operating properly.



Verifying That Your Oscilloscope s Disk Drive is Fully Expanded

---------------------------------------------------------------

You should always check that the disk drive is fully expanded after

performing an Operating System (OS) restore. If the disk has an issue,

a 160 GB hard drive may show no available disk space and appear to be

only 80 GB.



Perform the following steps to fix the issue with NO DATA LOSS:

1. On the desktop, right click on the computer ICON

2. Select  Manage

3. Click on  Disk Management

4. In the lower part of the window where you can see (C:) Healthy

(Boot, Page File, etc.), you may also see a large unallocated

partition next to it.

5. Right click in the C:\ partition and select  Extend Volume to

restore the unallocated partition to the C:

6. Follow the Wizard prompts



Network Security

----------------

Windows 7 contains an integrated software firewall that is enabled

by default. The enabled Windows 7 firewall may provide some protection

from Network worm-type viruses.



Anti-virus Protection

--------------------

If you connect this instrument to a network, we highly recommend

that you install antivirus software. Prior to leaving Tektronix,

this instrument was verified clean of known viruses.



Adobe Reader

------------

The Adobe Reader auto-update option is set to check for updates weekly.



To disable this auto-update option, complete the following steps:

1. After Adobe Reader is installed, launch the application.

2. From the menu, Edit->Preferences for Updates...

3. Uncheck the "Automatically check for Adobe updates" option.

4. Click OK.

5. After the update finishes, install any updates or select Cancel.



Product Upgrades

----------------

From time to time Tektronix releases new versions of the product

software or optional application software. Customers can download

these from the Tektronix web site at http://www.tek.com/downloads.

Be sure to read the  This SW Applies To: list of instruments to

be sure your model is listed.



Service Packs and Critical patches from Microsoft made available

during the development of the operating system for this instrument

were tested and included by Tektronix. Service Packs and Critical

patches released after the development of the operating system are

tested on an as needed basis by Tektronix.



To be notified of new instrument software releases, you can

subscribe to the Tektronix RSS feed for software and drivers at the

following URL: http://www.tek.com/rss/.



Remote PC Control Software Support

----------------------------------

This oscilloscope series supports Microsoft Remote Desktop. For

proper display functionality, the remote viewer should have its

resolution set to 1024 X 768 or full screen. Other settings may

cause display artifacts.



The keyboard Print Screen key may also be used to capture a full

screen shot of the display.



Software Licenses

-----------------

CppUnit 1.5

Tektronix has incorporated CppUnit 1.5 into the TekScope application

under the following license terms:



Permission to reproduce and create derivative works from the Software

("Software Derivative Works") is hereby granted to you under the

copyright of Michael Feathers. Michael Feathers also grants you the

right to distribute the Software and Software Derivative Works.



Michael Feathers licenses the Software to you on an "AS IS" basis,

without warranty of any kind. Michael Feathers HEREBY EXPRESSLY DISCLAIMS

ALL WARRANTIES OR CONDITIONS, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT

NOT LIMITED TO, THE IMPLIED WARRANTIES OR CONDITIONS OF MERCHANTABILITY,

NON INFRINGEMENT AND FITNESS FOR A PARTICULAR PURPOSE. You are solely

responsible for determining the appropriateness of using the Software and

assume all risks associated with the use and distribution of this

Software, including but not limited to the risks of program errors,

damage to or loss of data, programs or equipment, and unavailability or

interruption of operations. MICHAEL FEATHERS WILL NOT BE LIABLE FOR ANY

DIRECT DAMAGES OR FOR ANY SPECIAL, INCIDENTAL, OR INDIRECT DAMAGES OR FOR

ANY ECONOMIC CONSEQUENTIAL DAMAGES (INCLUDING LOST PROFITS OR SAVINGS),

EVEN IF MICHAEL FEATHERS HAD BEEN ADVISED OF THE POSSIBILITY OF SUCH

DAMAGE. Michael Feathers will not be liable for the loss of, or damage to,

your records or data, or any damages claimed by you based on a third party

claim.



You agree to distribute the Software and any Software Derivatives under a

license agreement that: 1) is sufficient to notify all licensees of the

Software and Software Derivatives that Michael Feathers assumes no

liability for any claim that may arise regarding the Software or Software

Derivatives, and 2) that disclaims all warranties, both express and

implied, from Michael Feathers regarding the Software and Software

Derivatives. (If you include this Agreement with any distribution of the

Software and Software Derivatives you will have meet this requirement).

You agree that you will not delete any copyright notices in the Software.



This Agreement is the exclusive statement of your rights in the Software

as provided by Michael Feathers. Except for the licenses granted to you

in the second paragraph above, no other licenses are granted hereunder,

by estoppel, implication or otherwise.



BouncyCastle

Copyright(c) 2000-2010 The Legion Of The Bouncy Castle

Tektronix has incorporated Bouncy Castle into the TekScope

application Which is an open source component. Permission is hereby

granted, free of charge, to any person obtaining a copy of this (the

Bouncy Castle) software and associated documentation files (the

 Software ), to deal in the Software without restriction, including

without limitation the rights to use, copy, modify, merge, publish,

distribute, sub-license, and/or sell copies of the Software, and to

permit persons to whom the Software is furnished to do so, subject to

the following conditions:



THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND,

EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF

MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND

NON-INFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS

BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN

ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN

CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE

SOFTWARE.



Intel(R) Integrated Performance Primitives (Intel IPP)

Tektronix has incorporated Intel(R) Integrated Performance

Primitives (Intel IPP)into the TekScope application under the

agreement of the end user license. THE MATERIALS AND INFORMATION

ARE PROVIDED "AS IS" WITH NO WARRANTIES, EXPRESS OR IMPLIED,

INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF

MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, NON-INFRINGEMENT

OF INTELLECTUAL PROPERTY RIGHTS, OR ANY WARRANTY OTHERWISE ARISING

OUT OF ANY PROPOSAL, SPECIFICATION, OR SAMPLE. If the media on

which the Materials are furnished are found to be defective in

material or workmanship under normal use for a period of ninety (90)

days from the date of receipt, Intel's entire liability and your

exclusive remedy shall be the replacement of the media. This offer

is void if the media defect results from accident, abuse,

or misapplication.



HDF5 (Hierarchical Data Format 5) Software Library and Utilities

Copyright 2006-2013 by The HDF Group.



NCSA HDF5 (Hierarchical Data Format 5) Software Library and Utilities

Copyright 1998-2006 by the Board of Trustees of the University of Illinois.



All rights reserved.



Redistribution and use in source and binary forms, with or without

modification, are permitted for any purpose (including commercial purposes)

provided that the following conditions are met:



1. Redistributions of source code must retain the above copyright notice,

this list of conditions, and the following disclaimer.



2. Redistributions in binary form must reproduce the above copyright notice,

this list of conditions, and the following disclaimer in the documentation

and/or materials provided with the distribution.



3. In addition, redistributions of modified forms of the source or binary

code must carry prominent notices stating that the original code was

changed and the date of the change.



4. All publications or advertising materials mentioning features or use of

this software are asked, but not required, to acknowledge that it was

developed by The HDF Group and by the National Center for Supercomputing

Applications at the University of Illinois at Urbana-Champaign and

credit the contributors.



5. Neither the name of The HDF Group, the name of the University, nor the

name of any Contributor may be used to endorse or promote products derived

from this software without specific prior written permission from

The HDF Group, the University, or the Contributor, respectively.



DISCLAIMER:

THIS SOFTWARE IS PROVIDED BY THE HDF GROUP AND THE CONTRIBUTORS

"AS IS" WITH NO WARRANTY OF ANY KIND, EITHER EXPRESSED OR IMPLIED. In no

event shall The HDF Group or the Contributors be liable for any damages

suffered by the users arising out of the use of this software, even if

advised of the possibility of such damage.



Contacting Tektronix

--------------------

MyTek - One way to receive timely information on new software updates,

new products from Tektronix and other useful information is to join the

Tektronix community. Visit www.tek.com/userto become a member.



Product Support - For application-oriented questions about a Tektronix

measurement product, in North America call 1-800-833-9200 option 3,

Monday-Friday, 6:00AM - 5:00PM Pacific Time or contact us by email at

techsupport@tektronix.com.



For service support call 1-800-833-9200 option 2, Monday-Friday,

5:00AM-5:00PM Pacific Time or contact us by email at

meas-svc-feedback@tektronix.com



Outside of North America: please contact your local Tektronix Sales or

Distributor office. Refer to our web site at www.tektronix.com for

listings of those offices.



For all other information call 1-800-833-9200, visit our web site at

www.tektronix.com, or write to us at:



Tektronix, Inc.

P.O. Box 500

Beaverton, OR 97077