Version: [3.06] Last Revised: [12/10/2013] Products: This firmware supports all MDO4000 Series oscilloscopes. History ------- v3.06 12/10/2013 New Features: - RBW range extended up to 200MHz - Spectrum trace reset - Spectrogram timestamps (rolling and slice) - RF power level trigger bandwidth readout - RF vertical position range extension to +-100 divs - Frequency vs. Time trace defaults to Span/10 - Phase vs. Time controls (reference point and wrap) - RF vs. Time traces have unique colors - RF vs. Time readouts indicating baseband bandwidth - RF vs. Time readouts indicating negative frequency (Start Freq. < DC) - Saving I&Q data to MATLAB Defects Fixed: - Fixed missing channel labels and vertical settings for channels 2 and 4 in saved CSV file. - Corrected vertical power value displayed in RF Probe Setup menu for TAP2500 and TDP1000 probes. - Fixed loss of channel data after channel is switched off then on again while acquisitions are in stop mode. - Fixed Socket Server Protocol None response to a query. The defect was that in raw socket mode, a second query was needed to clear out the instrument buffer which had new line and carriage return (LFCR). The defect was resolved by terminating all responses in raw socket mode with only the new line (LF). v2.94 2/11/2013: New Features: - Supports new TPA-N-PRE preamplifier accessory. Defects Fixed: - None v2.88 11/07/2012 Defects Fixed: - Support large TIQ files. - Add firmware update notifiers specifically for Signal Path Compensation (SPC) when required v2.86 10/19/2012 New Features: - New models supported: MDO4014-3 and MDO4034-3. - Improved TIQ file format. Defects Fixed: - Ethernet: fixed DHCP and IP Address settings such that they persist thru power cycle - Improved operation of power-up RF signal path compensation. - Updated two German translation strings. - Corrected cursor behavior for recall from setup file. - Improved performance of e*Scope PI queries. v2.52 4/16/12 Defects Fixed: - Added support for SCPI STATus abbreviation. - Fixed problem with cursor readouts appearing unexpectedly when cursor bars are moved while Menu Off is enabled. - Fixed incorrect display of FFT units that occurred after power cycling the instrument. - Fixed missing histogram in saved screen image when saved using the Save/Recall menu. - Fixed incorrect recall of saved setup when firmware update complete with DPO4LMT module installed. - Fixed time correlation between CH1 and CH2 after a single sequence acquisition that occurred with a large delay and > 1 M record length. - Display of waveform data no longer disappear when switching Delay between On and Off while in roll mode. - Display of channel 1 and channel 3 waveforms no longer disappear after single sequence acquisition and record length is >= 10 M. v2.20 11/21/11 New Features: - Enhanced Menu Off functionality to allow manipulation of cursors while readouts are turned off. - Added programmatic interface command to query noise density and phase noise. Defects Fixed: - Setup & Hold search no longer reports false positives. - Logic search on RF Versus Time traces now works correctly. - The Autoset enable/disable feature now works correctly. - Fixed rare instances when Single Sequence caused incorrect time correlation between analog channels and RF traces. - Notification message "external reference unlocked" added to notify user when the oscilloscope cannot lock to the 10 MHz REF IN external clock input. v2.10 9/2/11 Defects Fixed: - RF Auto Level feature works at all center frequency/span combinations. - Fixed incorrect time correlation between analog/digital/rf under certain conditions when acquisitions have been stopped with the Run/Stop button. - Eliminated "application error" message with R-To-Center button at certain settings. v2.08 8/11/11 Defects Fixed: - RF traces draw more smoothly while panning. - Eliminated excess jitter on channels 2 and 4 under certain conditions. - The amplitude of the RF Amplitude vs Time trace is now correctly calculated. - When RF is turned off, analog acquisition rate is now fully restored. - Search now works on digital channels when MagniVu is on. - Marker readouts now restored after toggling RF state off and on. - The numeric keypad now works correctly with the spectrogram slice number. - Spectrogram color map is now correct after a firmware upgrade. v2.06 7/28/11 v2.04 7/20/11 v2.02 7/13/11 Defects Fixed: - No user-visible changes through version 2.06